Humate p - HUMATE-P is contraindicated in individuals with a history of anaphylactic or severe systemic response to antihemophilic factor or von Willebrand factor preparations. Monitor for intravascular hemolysis and decreasing hematocrit values in patients with A, B, and AB blood groups who are receiving large or frequent doses.

 
HUMATE-P is contraindicated in individuals with a history of anaphylactic or severe systemic response to antihemophilic factor or von Willebrand factor preparations. Monitor for intravascular hemolysis and decreasing hematocrit values in patients with A, B, and AB blood groups who are receiving large or frequent doses.. Cars for sale in tulsa ok under dollar2 000

The NDC Packaged Code 63833-617-02 is assigned to a package of 1 kit in 1 carton * 15 ml in 1 vial (63833-627-01) * 15 ml in 1 vial, single-dose (63833-765-55) of Humate-p, a plasma derivative labeled by Csl Behring Gmbh. The product's dosage form is kit and is administered via form.See full list on drugs.com The generic name of Humate-p is antihemophilic factor/von willebrand factor complex (human). The product's dosage form is kit. The product is distributed in a single package with assigned NDC code 63833-617-02 1 kit in 1 carton * 15 ml in 1 vial (63833-627-01) * 15 ml in 1 vial, single-dose (63833-765-55). This page includes all the important ... Aug 7, 2023 · With the HUMATE-P vial placed firmly on a flat surface, invert the diluent vial with the Mix2Vial transfer set attached and push the plastic spike of the transparent adapter firmly through the center of the stopper of the HUMATE-P vial (Fig. 4). The diluent will automatically transfer into the HUMATE-P vial. HUMATE-P is a made in a multi-step process that provides purity and safety every step of the way. Plasma collection, processing, and packaging procedures are designed to retain the properties of the VWF and FVIII proteins. CSL Behring’s Integrated Safety System includes 3 steps specifically designed to identify and remove live viruses.Haemate P/Humate-P, the first plasma-derived von Willebrand factor (VWF)/factor VIII (FVIII)-containing concentrate that was pasteurized to reduce the risk of virus infection, was developed in the 1970s and approved for use in Germany in 1981. Today, Haemate P is marketed in over 35 countries worldw …In studies, more than 5% of patients reported the following adverse reactions to HUMATE-P: allergic/anaphylactic reactions, including hives, chest tightness, rash, itching, and swelling. The most common adverse reactions after surgery were bleeding at the wound or infusion site, and nosebleeds. Please see full prescribing information. Tradename: Humate-P. Manufacturer: CSL Behring GmbH, License #1765. Indication: In adult and pediatric patients with von Willebrand disease for (1) treatment of spontaneous and trauma-induced ... CSL Behring: Humate-P and Helixate using the Mix2Vial™ Grifols: Alphanate® and AlphaNine® S/D using the Mix2Vial™ (see the CSL Behring instructions for Humate-P) Novo Nordisk: NovoSeven® RT ; Octapharma: Wilate using the Mix2Vial™ (see the CSL Behring instructions for Humate-P)(Humate-P) VWD – control and prevention of bleeding episodes Type 1 VWD, mild disease Minor or major episodes: 40-60 IU/kg IV loading dose followed by 40- 50 IU/kg IV every 8-12 hours : Type 1 VWD, moderate or severe disease Minor episodes: 40-50 IU/kg IV as one or two doses . Major episodes: 50-75 IU/kg loading dose Humate-P® has a high degree of purity with a low amount of non-factor proteins. Fibrinogen is less than or equal to 0.2 mg/mL. Humate-P ® has a higher Factor potency than Humate-P Medicare Coverage and Co-Pay Details - GoodRx. ANTIHEMOPHILIC FACTOR prevents and treats bleeding episodes in people with hemophilia A or von Willebrand disease, conditions caused by low levels of blood clotting factors. It works by increasing these factor levels in your body. This helps your blood clot normally, which reduces bleeding.Humate-P® is derived from human plasma. As with all plasma-derived products, the risk of transmission of infectious agents, including viruses and, theoretically, the Creutzfeldt-Jakob disease (CJD) agent, cannot be completely eliminated. Although few adverse reactions have been reported in patients receiving Humate-P®, the most commonly reportedAmong the 63 VWD subjects who received HUMATE-P for prevention of excessive bleeding during and after surgery, including one subject who underwent colonoscopy without the planned polypectomy, the most common adverse events were postoperative hemorrhage (35 events in 19 subjects with five subjects experiencing bleeding at up to three different sites), postoperative nausea (15 subjects), and ... HUMATE-P is contraindicated in individuals with a history of anaphylactic or severe systemic response to antihemophilic factor or von Willebrand factor preparations. Monitor for intravascular hemolysis and decreasing hematocrit values in patients with A, B, and AB blood groups who are receiving large or frequent doses. Humate-P® is derived from human plasma. As with all plasma-derived products, the risk of transmission of infectious agents, including viruses and, theoretically, the Creutzfeldt-Jakob disease (CJD) agent, cannot be completely eliminated. Although few adverse reactions have been reported in patients receiving Humate-P®, the most commonly reported Humate P is the only product available for patients with von Willebrand Disease (VWD). Dose is based on VWF:RCo units only for VWD. VWF units varies in ratio to Factor VIII units with an average of 2.4:1. *Per Pharmacy & Therapeutics committee, Pharmacy can adjust dose within +/- 10% based on current dosage vial sizes in pharmacy to prevent waste.Sep 4, 2023 · HUMATE-P is contraindicated in individuals with a history of anaphylactic or severe systemic response to antihemophilic factor or von Willebrand factor preparations. Monitor for intravascular hemolysis and decreasing hematocrit values in patients with A, B, and AB blood groups who are receiving large or frequent doses. HUMATE-P (represented in the graph by the blue line) had the highest content of HMW-VWF multimers among VWF products tested, and its multimer pattern was most like that of NHP The multimer patterns of products A, G, H, and E (represented in the densitometric analysis by the red, green, orange, and yellow lines, respectively) differ from that of NHP Find patient medical information for Humate-P intravenous on WebMD including its uses, side effects and safety, interactions, pictures, warnings and user ratings. Humate-P • If patient needs FEIBA • If patient needs rFVIIa • If patient needs dose of DDAVP! Goal for factor replacement is 30 minutes or less for suspected head bleeds and 60 minutes or less for suspected bleeding in areas other than the head. Pearls: P1: When in doubt, administer clotting factor replacement therapy1. Humate-P** Humate P is a factor VIII and von Willebrand factor concentrate product made from the purified cold insoluble fraction of pooled human fresh frozen plasma It is used to treat and prevent bleeding in patients with a history of hemophilia A; and treatment of trauma induced bleeding andAmong the 63 VWD subjects who received HUMATE-P for prevention of excessive bleeding during and after surgery, including one subject who underwent colonoscopy without the planned polypectomy, the most common adverse events were postoperative hemorrhage (35 events in 19 subjects with five subjects experiencing bleeding at up to three different sites), postoperative nausea (15 subjects), and ... Factor VIII (plasma -derived)/von Willebrand Factor Complex (plasma -derived) [Alphanate or Humate -P], Factor VIII (plasma -derived) [Hemofil M or Koāte -DVI), and Factor VIII (recombinant) [Advate, Kogenate FS, Kovaltry, NovoEight, Nuwiq , or Recombinate ] are proven and medically necessary when both of the following c riteria are met:viral transmission. The primary viral reduction step of the Humate-P® manufacturing process is the heat treatment of the purified, stabilized aqueous solution at 60.0 +/ - 1°C for 10 hours. In addition, the purification procedure (several precipitation steps) used in the manufacture of Humate-P® also provides viral reduction capacity.The platelet bridges and VWF form layers, known as the initial hemostatic plug, which stops the bleeding at the injury site. 1. Successful completion of both stages of hemostasis results in the final step of the clotting process, the formation of a stable hemostatic plug. HUMATE-P has 94% homology with normal human plasma (NHP). 2.Riastap Tisseel Epoetin alfa (Epogen/Procrit) Albumin Cryoprecipitate Other(s): _____ Others ATryn Thrombate IIIHUMATE-P is made from human blood and could contain infectious agents. The risk that these agents may transmit disease cannot be completely eliminated, but has been reduced by screening plasma donors and testing donated plasma for certain viruses, and by inactivating and/or removing viruses during manufacturing. A. Alphanate, Humate-P ONLY Coverage is provided in the following conditions: Hemophilia A (congenital factor VIII deficiency) † • Diagnosis of congenital factor VIII deficiency has been confirmed by blood coagulation testing; AND Used as treatment for control and prevention of bleeding episodes (episodic treatmentImportant Safety Information for Humate-P. Antihemophilic Factor/von Willebrand Factor Complex (Human), HUMATE-P ® is indicated for treatment and prevention of bleeding in adult patients with hemophilia A (classical hemophilia). HUMATE-P is also indicated in adult and pediatric patients with von Willebrand disease (VWD) for (1) treatment of ...sudden cough, coughing up blood; pain, swelling, warmth, or redness in one or both legs; pale or yellowed skin, dark colored urine, fever, confusion or weakness; bleeding from a wound or where the medicine was injected; or. bleeding that is not controlled. Common Wilate side effects may include: nosebleeds;Antihemophilic Factor/von Willebrand Factor Complex (Human), HUMATE-P ® is approved to treat and prevent bleeding in adult patients with hemophilia A (classical hemophilia). HUMATE-P also treats spontaneous or trauma-induced bleeding episodes in adults and children with von Willebrand disease (VWD) and prevents excessive bleeding during and ...HUMATE-P is made from human blood and could contain infectious agents. The risk that these agents may transmit disease cannot be completely eliminated, but has been reduced by screening plasma donors and testing donated plasma for certain viruses, and by inactivating and/or removing viruses during manufacturing.Dose: individualize dose IV q8-24h until hemostasis; Info: estimated dose (units) = [wt (kg) x desired factor VIII level (%) x 0.5] where desired factor VIII level = 80-100%; 1 unit/kg will incr. factor VIII level approx. 2%; dose, duration varies by site/severity of bleeding, severity of deficiency, and presence of inhibitors. (Humate-P) VWD – control and prevention of bleeding episodes Type 1 VWD, mild disease Minor or major episodes: 40-60 IU/kg IV loading dose followed by 40- 50 IU/kg IV every 8-12 hours : Type 1 VWD, moderate or severe disease Minor episodes: 40-50 IU/kg IV as one or two doses . Major episodes: 50-75 IU/kg loading dose Humate-P® has a high degree of purity with a low amount of non-factor proteins. Fibrinogen is less than or equal to 0.2 mg/mL. Humate-P ® has a higher Factor potency than Humate-P: No adequate and well-controlled studies in pediatric patients with hemophilia A. Long-term evaluation of joint damage not available for pediatric patients; joint damage may result from suboptimal treatment of hemarthroses. Safety and efficacy established in infants, children, and adolescents with von Willebrand disease, but not in ...Dec 6, 2019 · Humate P/Haemate P Plasma derived North America/internationally CSL Behring, Germany 2.4 Pasteurization (60°C for 10 h) Voncento Plasma derived Europe CSL Behring, Germany 2.4 SD, dry heat (80°C, 72 h) Biostate Plasma derived Australia/Asia CSL Behring, Australia 2 SD, dry heat (80°C,72 h) Wilstart Plasma derived France HUMATE-P provides bleed control across all VWD types, including Type 3—the most severe. “Excellent” or “Good” overall clinical response demonstrated across the majority of treatment events in a retrospective study (N=97) *2. 424/437. treatment events. 332/344 nonsurgical.Possible side effects of Human Factor VIII with von Willebrand factor. Allergic reaction: Itching or hives, swelling in your face or hands, swelling or tingling in your mouth or throat, chest tightness, trouble breathing. Pain, itching, swelling, burning, or a lump under your skin where the needle was placed.Humate-P and Alphanate are currently the only plasma-derived VWF concentrates approved by the U.S. Food and Drug Administration for the treatment of VWD. These products also contain factor VIII ...Feb 1, 2023 · Humate-P; Wilate; Descriptions. Antihemophilic factor VIII and von Willebrand factor injection is a combination product that is used to treat serious bleeding episodes in patients with a bleeding problem called von Willebrand disease (VWD). The bleeding episode may be related to an injury (trauma) or a surgical procedure. Humate-P, Wilate) Reference Number: ERX.SPA.185 Effective Date: 01.11.17 Last Review Date: 11.17 Revision Log See Important Reminder at the end of this policy for important regulatory and legal information. Description The following are factor VIII/von Willebrand factor complexes (human) requiring prior authorization:Humate-P: No adequate and well-controlled studies in pediatric patients with hemophilia A. Long-term evaluation of joint damage not available for pediatric patients; joint damage may result from suboptimal treatment of hemarthroses. Safety and efficacy established in infants, children, and adolescents with von Willebrand disease, but not in ...Humate P: Adequate and well-controlled studies with long-term evaluation of joint damage have not been done. Wilate. Indicated for adolescents with hemophilia A as routine prophylaxis to reduce the frequency of bleeding episodes and for on-demand treatment and control of bleeding episodes; On-demand hemorrhage treatmentHUMATE-P is made from human blood and could contain infectious agents. The risk that these agents may transmit disease cannot be completely eliminated, but has been reduced by screening plasma donors and testing donated plasma for certain viruses, and by inactivating and/or removing viruses during manufacturing.viral transmission. The primary viral reduction step of the Humate-P® manufacturing process is the heat treatment of the purified, stabilized aqueous solution at 60.0 +/ - 1°C for 10 hours. In addition, the purification procedure (several precipitation steps) used in the manufacture of Humate-P® also provides viral reduction capacity. Obtain your Humate-P prescription for the set monthly price of $50.00 per month. Every year, thousands of Americans are prescribed Humate-P by their doctors to treat hemophilia A. However, filling a Humate-P prescription without coverage can force Americans to make difficult decisions about their care. As the nation’s fastest-growing pharmacy ...Haemate P/Humate-P, the first plasma-derived von Willebrand factor (VWF)/factor VIII (FVIII)-containing concentrate that was pasteurized to reduce the risk of virus infection, was developed in the 1970s and approved for use in Germany in 1981. Today, Haemate P is marketed in over 35 countries worldw … HUMATE-P is contraindicated in individuals with a history of anaphylactic or severe systemic response to antihemophilic factor or von Willebrand factor preparations. Monitor for intravascular hemolysis and decreasing hematocrit values in patients with A, B, and AB blood groups who are receiving large or frequent doses.Humate P - J7190 or J7186 or J7187 . Profilate HP- J7190 . AHF M - J7190 . Alphanate - J7190 . Antihemophilic Factor (Porcine) Hyate:C - J7191 . Recombinate (Recombinant) - J7192 . Kogenate - J7192 . Bioclate - J7192 . Helixate - J7192 . Xyntha – J7185 . 3. Factor VIII inhibitors . Autoplex T (anti-inhibitor) - J7198 . Feiba VH (anti ...Aug 28, 2023 · Humate-P: View Coupon: Humate-P Connect This program provides brand name medications at no or low cost: Provided by: CSL Behring: TEL: 800-676-4266 ALT PHONE: 844-727-2752 FAX: 844-727-2757: Languages Spoken: English. Program Website : Program Applications and Forms: Humate-P Connect Enrollment Form : Medications CSL Behring: Humate-P and Helixate using the Mix2Vial™ Grifols: Alphanate® and AlphaNine® S/D using the Mix2Vial™ (see the CSL Behring instructions for Humate-P) Novo Nordisk: NovoSeven® RT ; Octapharma: Wilate using the Mix2Vial™ (see the CSL Behring instructions for Humate-P) Aug 17, 2020 · In many cases, HUMATE-P from a single request was used for several treatment courses in one subject. Therefore, there are more reported treatment courses than requests. HUMATE-P was administered to 97 subjects in 530 treatment courses: 73 for surgery, 344 for treatment of bleeding, and 20 for prophylaxis of bleeding. Aetna considers Alphanate, Humate-P or Koate medically necessary for treatment of VWD when any of the following criteria is met: Member has type 1, 2A, 2M, or 2N VWD and has had an insufficient response to desmopressin or a documented clinical reason for not using desmopressin (see Appendix B ); or This Billing and Coding Article provides coding guidance for Hemophilia Factor Products. This article does not address payment determination for hemophilia factor products. Information on payment for the clotting factor as well as payment for a clotting factor furnishing fee may be found in CMS Internet-Only Manual (IOM) Publication 100-04 ...At CSL Behring, we believe everyone should have access to therapy. For HUMATE-P we provide support services to help you get the treatment you need. Co-pay Assistance: Patients meeting eligibility requirements* may receive up to $12,000 in Co-Pay support. *Patient must have coverage for HUMATE-P under a private, commercial plan.Humate P is the only product available for patients with von Willebrand Disease (VWD). Dose is based on VWF:RCo units only for VWD. VWF units varies in ratio to Factor VIII units with an average of 2.4:1. *Per Pharmacy & Therapeutics committee, Pharmacy can adjust dose within +/- 10% based on current dosage vial sizes in pharmacy to prevent waste.Lillicrap D, Poon M-C, Walker I, Xie F, Schwartz BA, and members of the Association of Hemophilia Clinic Directors of Canada. Efficacy and safety of the factor VIII/von Willebrand factor concentrate, Haemate-P/HUMATE-P: ristocetin cofactor unit dosing in patients with von Willebrand disease. Thromb Haemost. 2002;87 (2):224-230.Factor VIII (plasma -derived)/von Willebrand Factor Complex (plasma -derived) [Alphanate or Humate -P], Factor VIII (plasma -derived) [Hemofil M or Koāte -DVI), and Factor VIII (recombinant) [Advate, Kogenate FS, Kovaltry, NovoEight, Nuwiq , or Recombinate ] are proven and medically necessary when both of the following c riteria are met: Humate P - J7190 or J7186 or J7187 . Profilate HP- J7190 . AHF M - J7190 . Alphanate - J7190 . Antihemophilic Factor (Porcine) Hyate:C - J7191 . Recombinate (Recombinant) - J7192 . Kogenate - J7192 . Bioclate - J7192 . Helixate - J7192 . Xyntha – J7185 . 3. Factor VIII inhibitors . Autoplex T (anti-inhibitor) - J7198 . Feiba VH (anti ... Examples of plasma-derived product brand names include Humate P, Alphanate, Koate, and Wilfactin. An example of a product manufactured in the laboratory is Vonvendi. These treatments are injected into a vein, often in the hospital or in a health care provider's office, but some patients are taught how to self-inject this treatment at home.Haemate P/Humate-P is an intermediate-purity VWF/FVIII concentrate with extensive clinical experience in VWD. This concentrate has been shown to correct haemostatic defects of VWD, with efficacy ratings of good/excellent in nearly all patients treated for bleeding or surgical events.Berirab® P | Rabies Immunoglobulin. Evogam® | Human Normal Immunoglobulin 16% (16g/100mL) – Subcutaneous Infusion. HAEGARDA® | C1-Esterase Inhibitor Subcutaneous, (Human) Hepatitis B Immunoglobulin P | Human Hepatitis B Immunoglobulin. Hizentra® | Immune Globulin Subcutaneous (Human) 20% Liquid. Intragam® P | Human Normal Immunoglobulin.Jul 7, 2023 · Berirab® P | Rabies Immunoglobulin. Evogam® | Human Normal Immunoglobulin 16% (16g/100mL) – Subcutaneous Infusion. HAEGARDA® | C1-Esterase Inhibitor Subcutaneous, (Human) Hepatitis B Immunoglobulin P | Human Hepatitis B Immunoglobulin. Hizentra® | Immune Globulin Subcutaneous (Human) 20% Liquid. Intragam® P | Human Normal Immunoglobulin. HUMATE-P is made from human blood and could contain infectious agents. The risk that these agents may transmit disease cannot be completely eliminated, but has been reduced by screening plasma donors and testing donated plasma for certain viruses, and by inactivating and/or removing viruses during manufacturing.With the HUMATE-P vial placed firmly on a flat surface, invert the diluent vial with the Mix2Vial transfer set attached and push the plastic spike of the transparent adapter firmly through the center of the stopper of the HUMATE-P vial (Fig. 4). The diluent will automatically transfer into the HUMATE-P vial.Haemate P/Humate-P is an intermediate-purity VWF/FVIII concentrate with extensive clinical experience in VWD. This concentrate has been shown to correct haemostatic defects of VWD, with efficacy ratings of good/excellent in nearly all patients treated for bleeding or surgical events.Lillicrap D, Poon M-C, Walker I, Xie F, Schwartz BA, and members of the Association of Hemophilia Clinic Directors of Canada. Efficacy and safety of the factor VIII/von Willebrand factor concentrate, Haemate-P/HUMATE-P: ristocetin cofactor unit dosing in patients with von Willebrand disease. Thromb Haemost. 2002;87 (2):224-230.HUMATE-P provides reliable hemostatic control for all VWD types. HUMATE-P is also proven effective across multiple types of bleeds, including: All bleeding episodes, including spontaneous bleeding episodes (bleeding that occurs without an obvious cause) or after an injury, such as nosebleeds4. 97% of patients overall (100% Type 1, 100% Type 2 ...Factor VIII (plasma -derived)/von Willebrand Factor Complex (plasma -derived) [Alphanate or Humate -P], Factor VIII (plasma -derived) [Hemofil M or Koāte -DVI), and Factor VIII (recombinant) [Advate, Kogenate FS, Kovaltry, NovoEight, Nuwiq , or Recombinate ] are proven and medically necessary when both of the following c riteria are met: viral transmission. The primary viral reduction step of the Humate-P® manufacturing process is the heat treatment of the purified, stabilized aqueous solution at 60.0 +/ - 1°C for 10 hours. In addition, the purification procedure (several precipitation steps) used in the manufacture of Humate-P® also provides viral reduction capacity.Humate-P Coupons, Copay Cards and Rebates. Humate-P offers may take the form of printable coupons, rebates, savings or copay cards, trial offers, or free samples. Certain offers may be printable from a website while others may require registration, completing a questionnaire, or obtaining a sample from a medical professional. Failure to confirm specific third-party payor coding requirements may result in underpayment for Humate-P. Call 1-800-676-4266 for information on insurance matters or assistance with individual case inquiries on a variety of reimbursement services, including: claim processing reviews. appeals.The platelet bridges and VWF form layers, known as the initial hemostatic plug, which stops the bleeding at the injury site. 1. Successful completion of both stages of hemostasis results in the final step of the clotting process, the formation of a stable hemostatic plug. HUMATE-P has 94% homology with normal human plasma (NHP). 2. HUMATE-P is made from human blood and could contain infectious agents. The risk that these agents may transmit disease cannot be completely eliminated, but has been reduced by screening plasma donors and testing donated plasma for certain viruses, and by inactivating and/or removing viruses during manufacturing. Lillicrap D, Poon M-C, Walker I, Xie F, Schwartz BA, and members of the Association of Hemophilia Clinic Directors of Canada. Efficacy and safety of the factor VIII/von Willebrand factor concentrate, Haemate-P/HUMATE-P: ristocetin cofactor unit dosing in patients with von Willebrand disease. Thromb Haemost. 2002;87 (2):224-230.Lillicrap D, Poon M-C, Walker I, Xie F, Schwartz BA, and members of the Association of Hemophilia Clinic Directors of Canada. Efficacy and safety of the factor VIII/von Willebrand factor concentrate, Haemate-P/HUMATE-P: ristocetin cofactor unit dosing in patients with von Willebrand disease. Thromb Haemost. 2002;87 (2):224-230. The NDC Packaged Code 63833-617-02 is assigned to a package of 1 kit in 1 carton * 15 ml in 1 vial (63833-627-01) * 15 ml in 1 vial, single-dose (63833-765-55) of Humate-p, a plasma derivative labeled by Csl Behring Gmbh. The product's dosage form is kit and is administered via form.Dec 6, 2019 · Humate P/Haemate P Plasma derived North America/internationally CSL Behring, Germany 2.4 Pasteurization (60°C for 10 h) Voncento Plasma derived Europe CSL Behring, Germany 2.4 SD, dry heat (80°C, 72 h) Biostate Plasma derived Australia/Asia CSL Behring, Australia 2 SD, dry heat (80°C,72 h) Wilstart Plasma derived France Humate-P • If patient needs FEIBA • If patient needs rFVIIa • If patient needs dose of DDAVP! Goal for factor replacement is 30 minutes or less for suspected head bleeds and 60 minutes or less for suspected bleeding in areas other than the head. Pearls: P1: When in doubt, administer clotting factor replacement therapyHumate-P, Wilate) Reference Number: ERX.SPA.185 Effective Date: 01.11.17 Last Review Date: 11.17 Revision Log See Important Reminder at the end of this policy for important regulatory and legal information. Description The following are factor VIII/von Willebrand factor complexes (human) requiring prior authorization:HUMATE-P is contraindicated in individuals with a history of anaphylactic or severe systemic response to antihemophilic factor or von Willebrand factor preparations. Monitor for intravascular hemolysis and decreasing hematocrit values in patients with A, B, and AB blood groups who are receiving large or frequent doses.The generic name of Humate-p is antihemophilic factor/von willebrand factor complex (human). The product's dosage form is kit. The product is distributed in a single package with assigned NDC code 63833-617-02 1 kit in 1 carton * 15 ml in 1 vial (63833-627-01) * 15 ml in 1 vial, single-dose (63833-765-55). This page includes all the important ... Jan 17, 2012 · Humate-P, Wilate) Reference Number: ERX.SPA.185 Effective Date: 01.11.17 Last Review Date: 11.17 Revision Log See Important Reminder at the end of this policy for important regulatory and legal information. Description The following are factor VIII/von Willebrand factor complexes (human) requiring prior authorization: Jan 8, 2019 · This Billing and Coding Article provides coding guidance for Hemophilia Factor Products. This article does not address payment determination for hemophilia factor products. Information on payment for the clotting factor as well as payment for a clotting factor furnishing fee may be found in CMS Internet-Only Manual (IOM) Publication 100-04 ... Humate-P Alternatives Compared. Humate-P (antihemophilic factor/von willebrand factor) Desmopressin. DDAVP (desmopressin) Prescription only. Prescribed for von Willebrand Disease, Hemophilia A. Humate-P may also be used for purposes not listed in this medication guide. Prescription only.

Antihemophilic factor/VWF complex (Alphanate ®, Humate-P ®, Wilate ®) Full length with VWF: Pooled human plasma: 12.2–17.9 hours: 1978 (Alphanate), 1986 (Humate-P), August 2009 (Wilate) Recombinant: first generation: Antihemophilic factor recombinant (Recombinate ®) Full length: BSA in culture and human albumin as stabilizer: 14.6 ± 4.9 .... Kel tec sub 2000 40 cal drum

humate p

Additionally, Humate-P has a potency that is a higher factor than cryoprecipitate preparations. Humate-P can also be used for pediatric patients with VWD in the treatment of spontaneous and trauma-induced bleeding episodes, and the prevention of excessive bleeding during and after surgery.Aug 5, 2023 · HUMATE-P is made from human blood and could contain infectious agents. The risk that these agents may transmit disease cannot be completely eliminated, but has been reduced by screening plasma donors and testing donated plasma for certain viruses, and by inactivating and/or removing viruses during manufacturing. Dose: individualize dose IV q8-24h until hemostasis; Info: estimated dose (units) = [wt (kg) x desired factor VIII level (%) x 0.5] where desired factor VIII level = 80-100%; 1 unit/kg will incr. factor VIII level approx. 2%; dose, duration varies by site/severity of bleeding, severity of deficiency, and presence of inhibitors. Jun 23, 2020 · Use Humate-P (Antihemophilic And Von Willebrand Factor Complex) exactly as directed on the label, or as prescribed by your doctor. Do not use in larger or smaller amounts or for longer than ... 1. Humate-P** Humate P is a factor VIII and von Willebrand factor concentrate product made from the purified cold insoluble fraction of pooled human fresh frozen plasma It is used to treat and prevent bleeding in patients with a history of hemophilia A; and treatment of trauma induced bleeding andExamples of plasma-derived product brand names include Humate P, Alphanate, Koate, and Wilfactin. An example of a product manufactured in the laboratory is Vonvendi. These treatments are injected into a vein, often in the hospital or in a health care provider's office, but some patients are taught how to self-inject this treatment at home.Hemophilia A. Minor hemorrhage: Loading dose 15 IU/kg IV should achieve FVIII:C plasma level ~30% of normal. Moderate hemorrhage: Loading dose 25 IU/kg IV should achieve FVIII:C plasma level ~50% of normal. Life-threatening hemorrhage: 40-50 IU/kg IV initially, followed by 2-25 IU q8-12hr to maintain FVIII:C level at 80-100% of normal.HUMATE-P is contraindicated in individuals with a history of anaphylactic or severe systemic response to antihemophilic factor or von Willebrand factor preparations. Monitor for intravascular hemolysis and decreasing hematocrit values in patients with A, B, and AB blood groups who are receiving large or frequent doses.Aug 28, 2023 · Humate-P: View Coupon: Humate-P Connect This program provides brand name medications at no or low cost: Provided by: CSL Behring: TEL: 800-676-4266 ALT PHONE: 844-727-2752 FAX: 844-727-2757: Languages Spoken: English. Program Website : Program Applications and Forms: Humate-P Connect Enrollment Form : Medications Aug 5, 2023 · HUMATE-P is made from human blood and could contain infectious agents. The risk that these agents may transmit disease cannot be completely eliminated, but has been reduced by screening plasma donors and testing donated plasma for certain viruses, and by inactivating and/or removing viruses during manufacturing. humate-p Savings, Coupons and Information. | ANTIHEMOPHILIC FACTOR (an tee hee moe FIL ik fak tir) prevents and treats bleeding episodes in people with hemophilia A or von Willebrand disease, conditions caused by low levels of blood clotting factors. It works by increasing these factor levels in your body.Humate-P® has a high degree of purity with a low amount of non-factor proteins. Fibrinogen is less than or equal to 0.2 mg/mL. Humate-P ® has a higher Factor potency than In studies, more than 5% of patients reported the following adverse reactions to HUMATE-P: allergic/anaphylactic reactions, including hives, chest tightness, rash, itching, and swelling. The most common adverse reactions after surgery were bleeding at the wound or infusion site, and nosebleeds. Please see full prescribing information.What is HUMATE-P HUMATE-P is a VWF/FVIII replacement therapy that delivers results, patient after patient, treatment after treatment, decade after decade, as proven by a US study of the hemostatic efficacy of HUMATE-P. Based on this study, an independent Data Safety Monitoring Board judged hemostatic efficacy as "effective in 94.3% of the perioperative study subjects."Dosing Overview. HUMATE-P is labeled in VWF:RCo for dosing accuracy in VWD: Treatment of bleeding episodes: Administer 40–80 IU VWF:RCo per kg body weight every 8–12 hours. Prevention of excessive bleeding during and after surgery: Surgical dosing differs by type of surgery (ie, major, minor) and should be customized to patient need ...Humate-P® Humate-P ®, FDA approved in 1986, is an anti-hemophilic factor/von Willebrand factor complex (human) originally indicated for the treatment and prevention of bleeding in adults with hemo-philia A. In 1999, the FDA approved Humate-P® for adults and pediatric patients with VWD for the treatment of spontaneous and trauma-induced Feb 20, 2023 · sudden cough, coughing up blood; pain, swelling, warmth, or redness in one or both legs; pale or yellowed skin, dark colored urine, fever, confusion or weakness; bleeding from a wound or where the medicine was injected; or. bleeding that is not controlled. Common Wilate side effects may include: nosebleeds; Humate-P Coupons, Copay Cards and Rebates. Humate-P offers may take the form of printable coupons, rebates, savings or copay cards, trial offers, or free samples. Certain offers may be printable from a website while others may require registration, completing a questionnaire, or obtaining a sample from a medical professional. Antihemophilic Factor/von Willebrand Factor Complex (Human), HUMATE-P ® is approved to treat and prevent bleeding in adult patients with hemophilia A (classical hemophilia). HUMATE-P also treats spontaneous or trauma-induced bleeding episodes in adults and children with von Willebrand disease (VWD) and prevents excessive bleeding during and ... .

Popular Topics